Call Us: 01707 802233

Default welcome msg!

Categories

  • Categories
  • Battery
  • Heat Alarm
  • Smoke Alarm
  • Electrical
  • Induction Loop Kits
  • Power Supply Units
  • Plugs and Sockets
  • Fire Safety
  • Carbon Monoxide Alarms
  • Battery CO Alarms
  • Mains CO Alarms
  • Test Kits
  • Smoke and Heat alarms
  • Mains smoke alarms
  • Mains heat alarms
  • Battery smoke alarms
  • Battery heat alarms
  • Testing kits
  • Accessories
  • Fire Alarm Systems
  • Two Wire Conventional
  • Four Wire Conventional
  • Addressable
  • Fire Extinguishers and Blankets
  • Blankets
  • Extinguishers
  • Home Safety
  • Lighting
  • Home Lighting
  • Bathroom Lighting
  • Display Lighting
  • Downlights
  • Fire Rated Downlights
  • Night Light
  • Vintage Lighting
  • Security
  • Exit Devices
  • Break Glass
  • Exit buttons
  • Wireless
  • Infrared
  • Firemans Switch
  • Evacuation Devices
  • Door Retaining Magnets
  • Refuge Systems
  • Nurse Call Systems
  • Disabled Persons Toilet Alarm Kits
  • 800 series
  • Quantec
  • Dementia Care
  • Vehicle Cameras
  • Your shopping cart is empty!

Sigtel 8 Line Master EVC Controller - no handset.

Sigtel 8 Line Master EVC Controller - no handset.

  • Brand: CTEC
  • Product Code: ECU-8NT
  • Availability: 3-5 Days

£926.71 Inc VAT £772.26 Ex VAT

Sigtel 8 Line Master EVC Controller - no handset.

A Sigtel 8 line master controller which comes with display only.

Does not include a handset - ideal for use on networked SigTEL systems that do not require multiple control points.

Can be connected to up to eight disabled refuge or fire telephone outstations and is expandable to 16 lines using an ECU-8 expansion unit.

Networking facility allows up to four controllers (plus any expansion units) to be interlinked allowing systems of up to 64 lines to be implemented.

Supplied with a backlit LCD display.

Unique ‘auto-learn’ facility allows fast system set up.

Can be semi-flush mounted using an AFP385 bezel.

Operation can be maintained for 24 hours (standby) and 3 hours (in use)

Easily interfaced to NC951 accessible toilet alarms, PDA audio-frequency induction loop systems, strobes, CCTV activation relays, etc.

Requires 2 x 7.0Ah lead-acid batteries.


Approvals/certifications                           Facilitates compliance with BS5839-9 when correctly installed.
Mains supply                                              230V 50/60Hz.
Mains rated current                                  500mA.
Internal power supply                              19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to               1.5A @ 230Vac
Quiescent current                                     100mA (controller with fault buzzer sounding) plus 1mA per Type A outstation and 3.2mA per Type B outstation.
Max battery size and type                        2 x 12V 7Ah VRLA connected in series.
No. of lines                                                  8 (expandable to 16 via an ECU-8S 8 line expansion unit).
Auxiliary relays                                          Changeover fault relay (failsafe). 30V 1A max.
Open collector outputs                            (OP1): Activates when the ECU is ringing; (OP2) Activates when there is an active accessible toilet alarm call; (OP3) Closes when the handset is off hook and                                                                       remains active for 2 mins after it is replaced. 24V, 50mA max.
Other outputs                                            +24 V. Typically used to supply power to equipment connected to the ECU's open collector outputs (relays, etc).
Engineer (AL3) functions                          Engineer mode and reset buttons (internal).
Indicators                                                   128 x 64 pixel LCD display; Disablememt; System fault; PSU fault; General fault; Power on.
Controls                                                      Silence Buzzer. Other controls are available but are not applicable as no handset is provided on this unit.
Expansion connections                            2 x CAT5 connectors provided for an optional ECU-8S expansion unit (leads supplied with ECU-8S). ECU721 network card allows the connection of up to 3                                                                      additional ECU-4/8 controllers (1 x ECU721 per ECU-4/8).
Product dimensions (mm)                       410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid).
Construction & finish                               Metal lid and base, RAL7035 grey texture.
IP Rating                                                      IP20.
Weight                                                        3.1kg (without batteries).
Operating conditions/temperature      -5ºC to +40ºC. Max relative humidity: 95%.