Call Us: 01707 802233

Default welcome msg!

Categories

  • Categories
  • Battery
  • Heat Alarm
  • Smoke Alarm
  • Electrical
  • Induction Loop Kits
  • Power Supply Units
  • Plugs and Sockets
  • Fire Safety
  • Carbon Monoxide Alarms
  • Battery CO Alarms
  • Mains CO Alarms
  • Test Kits
  • Smoke and Heat alarms
  • Mains smoke alarms
  • Mains heat alarms
  • Battery smoke alarms
  • Battery heat alarms
  • Testing kits
  • Accessories
  • Fire Alarm Systems
  • Two Wire Conventional
  • Four Wire Conventional
  • Addressable
  • Fire Extinguishers and Blankets
  • Blankets
  • Extinguishers
  • Home Safety
  • Lighting
  • Home Lighting
  • Bathroom Lighting
  • Display Lighting
  • Downlights
  • Fire Rated Downlights
  • Night Light
  • Vintage Lighting
  • Security
  • Exit Devices
  • Break Glass
  • Exit buttons
  • Wireless
  • Infrared
  • Firemans Switch
  • Evacuation Devices
  • Door Retaining Magnets
  • Refuge Systems
  • Nurse Call Systems
  • Disabled Persons Toilet Alarm Kits
  • 800 series
  • Quantec
  • Dementia Care
  • Vehicle Cameras
  • Your shopping cart is empty!

CTEC CFP Alarmsense Conventional 4 zone panel Two Wire CFP704-2

  • Brand: CTEC
  • Product Code: CFP704-2
  • Availability: 3-5 Days

£231.92 Inc VAT £193.27 Ex VAT

CTEC CFP AlarmSense Conventional 4 zone panel (Two Wire)

CFP Alarmsense 4 zone, two-wire fire panel.

The CFP704-2 includes four AlarmSense zones, four conventional sounder circuits, class change & alert inputs and onboard fire & fault relays.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities

Includes 4 AlarmSense zone circuits.

Note: requires 2 x 3.4Ah lead acid batteries.

For use only with Apollo AlarmSense two-wire detectors, call points and sounders.


Approvals/certifications                                      Certified to EN54-2/4 by the LPCB (0832-CPR-F0386)
Mains supply                                                         230V 50/60Hz
Mains rated current                                             350mA maximum
Internal power supply                                         19V-28.5V (27V nominal). Ripple 7V maximum (battery fault)
Total output current limited to                          1.5A @ 230Vac (ImaxA eq 146mA)
Quiescent current                                                25mA (mains failed, internal sounder active, PSU & gen fault LED lit)
Max battery size and type                                  2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah
No. of detector zone circuits                             The CFP704-2 has 4 AlarmSense zone circuits which are compatible with Apollo's AlarmSense range of detectors & call points AND sounders & visual   indicators. (Max. length per circuit is 500m)
Call point resistor value                                      Only use AlarmSense call points
Max. devices per detector zone                        25 AlarmSense detectors/manual call points per AlarmSense zone. For AlarmSense sounder limitations per AlarmSense zone see 'Max. sounder output current' section
No. of conventional sounder circuits                4 - these are additional conventional (non-AlarmSense) sounder circuits; Max. length per circuit is 500m.
EOL resistor value                                               6800Ω 5% Tol. 0/25W (blue, grey, red, gold)
Alarm voltage                                                       27V max, 20V min (final battery voltage)
Max. sounder output current                            Each AlarmSense zone circuit & each conventional sounder circuit will support a max. sounder current of 200mA. Distribute sounder loads as evenly as possible. Total sounder loading per panel should not exceed 1.25A
Auxiliary relays                                                    Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc
Open collector outputs                                      Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage 27Vdc)
Other outputs                                                      24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed)
Expansion connections                                       Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards
Product dimensions (mm)                                  380 W x 235 H x D 96mm
Construction & finish                                          Plastic lid and base; RAL7035 textured
IP Rating                                                                 IP30
Weight                                                                    1.75kg (without batteries)