Call Us: 01707 802233

Default welcome msg!

Categories

  • Categories
  • Battery
  • Heat Alarm
  • Smoke Alarm
  • Electrical
  • Induction Loop Kits
  • Power Supply Units
  • Plugs and Sockets
  • Fire Safety
  • Carbon Monoxide Alarms
  • Battery CO Alarms
  • Mains CO Alarms
  • Test Kits
  • Smoke and Heat alarms
  • Mains smoke alarms
  • Mains heat alarms
  • Battery smoke alarms
  • Battery heat alarms
  • Testing kits
  • Accessories
  • Fire Alarm Systems
  • Two Wire Conventional
  • Four Wire Conventional
  • Addressable
  • Fire Extinguishers and Blankets
  • Blankets
  • Extinguishers
  • Home Safety
  • Lighting
  • Home Lighting
  • Bathroom Lighting
  • Display Lighting
  • Downlights
  • Fire Rated Downlights
  • Night Light
  • Vintage Lighting
  • Security
  • Exit Devices
  • Break Glass
  • Exit buttons
  • Wireless
  • Infrared
  • Firemans Switch
  • Evacuation Devices
  • Door Retaining Magnets
  • Refuge Systems
  • Nurse Call Systems
  • Disabled Persons Toilet Alarm Kits
  • 800 series
  • Quantec
  • Dementia Care
  • Vehicle Cameras
  • Your shopping cart is empty!

CTEC CFP Alarmsense Conventional 2 zone panel Two Wire CFP702-2

  • Brand: CTEC
  • Product Code: CFP702-2
  • Availability: 3-5 Days

£186.90 Inc VAT £155.75 Ex VAT

CTEC CFP AlarmSense Conventional 2 zone panel (Two Wire)

CFP Alarmsense 2 zone, two-wire fire panel.

The CFP702-2 includes two AlarmSense zones, four conventional sounder circuits, class change & alert inputs and onboard fire & fault relays.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities

Includes 2 AlarmSense zone circuits.

Note: requires 2 x 3.4Ah lead acid batteries.

For use only with Apollo AlarmSense two-wire detectors, call points and sounders.


Approvals/certifications                           Certified to EN54-2/4 by the LPCB (0832-CPR-F0386)
Mains supply                                              230V 50/60Hz
Mains rated current                                  350mA maximum
Internal power supply                              19V-28.5V (27V nominal). Ripple 7V maximum (battery fault)
Total output current limited to               1.5A @ 230Vac (ImaxA eq 146mA)
Quiescent current                                     25mA (mains failed, internal sounder active, PSU & gen fault LED lit)
Max battery size and type                        2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah
No. of detector zone circuits                   The CFP702-2 has 2 AlarmSense zone circuits which are compatible with Apollo's AlarmSense range of detectors & call points AND sounders & visual indicators       Max. devices per detector zone              25 AlarmSense detectors/manual call points per AlarmSense zone                      
No. of conventional sounder circuits     4 - these are additional conventional (non-AlarmSense) sounder circuits; Max. length per circuit is 500m
EOL resistor value                                      6800Ω 5% Tol. 0/25W (blue, grey, red, gold)
Alarm voltage                                             27V max, 20V min (final battery voltage)
Max. sounder output current                  Each AlarmSense zone circuit conventional sounder circuit will support a max.  current of 200mA. Total sounder loading per panel should not exceed 1.25A
Expansion connections                             Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards
Product dimensions (mm)                       380 W x 235 H x D 96mm
Construction & finish                               Plastic lid and base; RAL7035 textured
IP Rating                                                     IP30
Weight                                                        1.75kg (without batteries)